Enter your slab dimensions and spacing to see total rebar needed.
Lay out a rebar grid for a slab and get everything you need to order: bar counts in each direction, total length with waste, total weight, and how many standard-length sticks that translates to.
Enter your slab dimensions and spacing to see total rebar needed.
Bars run in both directions at your on-center spacing. The calculator computes how many bars fit each way (rounding to include the closing bar at each edge), multiplies by the run lengths, adds your waste percentage for lap splices and trimming, and converts total length to weight using the standard weight of your bar size.
US bar numbers describe diameter in eighths of an inch: #3 is 3/8 in (9.5 mm) at 0.376 lb/ft, #4 is 1/2 in (12.7 mm) at 0.668 lb/ft, and #5 is 5/8 in (15.9 mm) at 1.043 lb/ft. Slabs commonly use #3 or #4 at 12–18 inches on-center; structural elements use larger bars per design.